Deoiling hydrocyclone

A hydrocyclone skid with a boost pump of progressive cavity type installed of a single liner is to be used for testing the practical produced water at specific field conditions. With that test deoilding hydrocyclone skid, it would be able to foresee the real result if the hydrocyclone liners to be used for the exact filed and operational conditions.

Products Details

Production Capacities & Properties

 
 

Min

Normal

Max

Gross liquid Stream (cu m/hr)

0.73

2.4

2.4

Oil concentration(ppm) ,max.

-

1000

2000

Oil density (kg/m3)

-

816

-

Dynamic viscosity of oil(Pa.s)

-

-

-

Water density(kg/m3)

-

1040

-

Fluids temperature(oC)

23

30

45

Sand concentration (> 45 micron) ppmvwater

N/A

N/A

N/A

Sand density (kg/m3)

N/A

Pump power (electricity)With a START/STOP switcher

50Hz, 380VAC, 3P, 1.1 KW

Inlet/Outlet Conditions  

Min

Normal

Max

Operating pressure (kPag)

500

1000

1000

Operating temperature (oC)

23

30

45

Oil outlet pressure (kPag)

<150

Water outlet pressure (kPag)

570

570

Produced water specification, ppm

< 30

 
Pump Inlet 2” 150#ANSI RFWN
Hydrocyclone Inlet 1” 300#ANSI RFWN
Water Outlet 1” 150# NPT/Quick Disconn.
Oil Outlet 1” 150# NPT/Quick Disconn.
 1600mm (L) x 620mm (W) x 1200mm (H)440 kg

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours